This test reproduces the efforts of a well-equipped individual attempting to to force entry. This test is conducted in three phases. First, testers try to force open the window using tools like a knife blade, a screwdriver, and wire. They then attach a cable to strategic points on the window and apply increasing loads. If the window does not give, they use tools again in a third attempt.
Windows rated F2 have successfully passed the test at level 10. Modern Series 9500/9600 Windows are rated F2, level 40.
|
|
Load Orientation
|
| A |
Parallel to the window from the handle |
| B |
Perpendicular to the window from the handle, first by pulling then pushing |
| C |
Parallel to the window at center of the sash, from the bottom upward |
| D |
Perpendicular to the window where sashes meet, toward the interior |
|